Specifications |
|
700 VA |
1000 VA |
1500 VA |
2000 VA |
3000 VA |
|
Rating (VA/W) |
700 VA/630W |
1000 VA/900W |
1500 VA/1350W |
2000 VA/1800W |
3000 VA/2700W |
|
Format |
Tower |
Tower or Rack 2U |
|
Electrical characteristics |
Technology |
On-line double-conversion with Power Factor Correction (PFC) system |
|
Nominal voltage |
200/208/220/230/240V |
|
Input voltage range |
190-276V without derating (up to 120-276V with derating) |
200-276V without derating (up to 140-276V with derating) |
|
Input frequency range/THDI |
40-70Hz, 50/60Hz autoselection, frequency converter mode |
|
Connections |
Input |
1 IEC C14 (10A) |
1 IEC C14 (10A) |
1 IEC C14 (10A) |
1 IEC C14 (10A) |
1 IEC C20 (16A) |
|
Outputs |
6 IEC C13 (10A) sockets |
6 IEC C13 (10A) sockets |
6 IEC C13 (10A) sockets |
8 IEC C13 (10A) sockets |
8 IEC C13 (10A) sockets + 1 IEC C19 (16A) socket |
Switched Outlet Group |
2 outlet groups |
|
Batteries |
Typical backup times* (minutes)/load |
300W |
500W |
800W |
1200W |
1800W |
2500W |
9SX 700 |
14 |
7.5 |
|
|
|
|
9SX 1000 |
24 |
14 |
7 |
|
|
|
9SX 1000 + 1 EBM/+ 4 EBM |
90/320 |
56/200 |
33/120 |
|
|
|
9SX 1500 |
39 |
23 |
12 |
7 |
|
|
9SX 1500 + 1 EBM/+4 EBM |
142/520 |
85/310 |
50/179 |
31/115 |
|
|
9SX 2000 (Tower) |
62 |
36 |
22 |
13 |
7 |
|
9SX 2000 (Tower) + 1 EBM/+4 EBM |
280/1050 |
165/620 |
100/390 |
65/250 |
40/160 |
|
9SX 2000 (Rack) |
42 |
25 |
14 |
8 |
4.5 |
|
9SX 2000 (Rack) + 1 EBM/+4 EBM |
210/800 |
120/480 |
72/270 |
45/175 |
30/118 |
|
9SX 3000 (Tower) |
78 |
45 |
29 |
17 |
10 |
6 |
9SX 3000 (Tower) + 1 EBM/+4 EBM |
290/1100 |
175/630 |
108/421 |
68/255 |
45/168 |
30/112 |
9SX 3000 (Rack) |
57 |
33 |
20 |
12 |
7 |
4 |
9SX 3000 (Rack) + 1 EBM/+4 EBM |
220/820 |
125/490 |
77/280 |
50/180 |
32/121 |
22/81 |
Battery management |
ABM® and Temperature compensated charging method (user selectable), automatic battery test, deep discharge protection, automatic recognition of external battery units. |
Communication |
Communication ports |
1 USB port + 1 serial RS232 port + 1 mini-terminal block for Remote Power Off + 1 mini-terminal block for Output relay |
|
Communication slot |
1 slot for Network-M2, Network-MS, ModBus-MS or Relay-MS cards |
|
Operating conditions, standards and approvals |
Operating temperature |
0 to 40°C |
|
Typical noise level |
40dB |
41dB |
43dB |
45dB |
45dB |
|
Safety |
IEC/EN 62040-1, UL 1778, CSA 22.2 |
|
EMC |
IEC/EN 62040 -2 , FCC Class B, CISPR22 Class B |
|
Approvals & marking |
CE /CB report (TUV) / cULus / EAC / RCM / BIS (Tower models only) / KCC (Tower models only) |
|
Dimensions H x W x D in mm/Weight |
UPS |
252x160x357/11.5kg |
Tower: 252x160x387/14.8kg Rack: 86.5x438x438/15.7kg |
Tower: 252x160x437/18.5kg Rack: 86.5x438x438/18.4kg |
Tower: 346x214x412/33.3kg Rack: 86.5x438x608/26.5kg |
Tower: 346x214x412/33.4kg Rack: 86.5x438x608/26.5kg |
|
EBM |
|
Tower: 252x160x387/19kg Rack: 86.5x438x438/22.2kg |
Tower: 252x160x387/24.5kg Rack: 86.5x438x438/27.4kg |
Tower: 346x214x412/48.7kg Rack: 86.5x438x608/40.5kg |
Tower: 346x214x412/48.7kg Rack: 86.5x438x608/40.5kg |
|